High Efficiency DC Brushless Horizontal Concealed Fan Coil Unit

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

High Efficiency DC Brushless Horizontal Concealed Fan Coil Unit

  • 1
  • 2

Brand Name : EuroKlimat

Model Number : EKCW-D

Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC

Place of Origin : China

MOQ : 5 pcs

Price : Negotiation

Payment Terms : T/T or L/C

Supply Ability : 15,000pcs per month

Delivery Time : 10 working days after received your payment

Packaging Details : Plywood

Product Name : DC Fan Coil Unit

Installation : Ceiling hang

Cooling Capacity(kW) : 1.69-11.54-

Heating Capacity(kW) : 3.28-18.49

Air Flow(m3/s) : 279-1673

ESP (Pa) External Static Pressure : 0-50

Return Air Plenum : Optional

Electric Heater : Optional

Aluminum Fins : Shutter-type hyperbolic and hydrophilic fins

Test Pressure (Mpa) : 3.3

Contact Now

12.1 High Efficiency Low Sound Level DC Brushless Horizontal Concealed Fan Coil Unit

Specifications:(two-pipe with 2 Rows of Coils)

Model
Performance
EKCW
200ATD
EKCW
300ATD
EKCW
400ATD
EKCW
500ATD
EKCW
600ATD
EKCW
800ATD
EKCW
1000ATD
EKCW
1200ATD
Rated air flow (m3/h; under static pressure of 12
Pa and 30 Pa)
H 340 510 680 850 1020 1360 1700 2040
M 279 418 558 697 836 1115 1394 1673
L 170 255 340 425 510 680 850 1020
Rated cooling capacity (W) Total heating/cooling capacity H 1770 2955 3920 4635 5115 7610 8680 10495
Sensible heating/cooling capacity H 1140 1980 2570 3205 3735 5535 6680 7765
Rated heating capacity (W) H 3280 5120 6450 7560 9095 12830 15865 18485
Rated input power (W) Static pressure of 12 Pa H 23 34 41 53 68 97 120 156
M 16 22 27 36 45 65 80 100
L 8 11 14 18 23 33 41 39
Static pressure of 30 Pa H 31 42 57 65 84 112 144 182
M 19 27 36 41 53 71 91 111
L 10 14 19 22 28 37 48 60
Working current (A) Static pressure of 12 Pa H 0.11 0.16 0.20 0.25 0.32 0.46 0.57 0.75
Static pressure of 30 Pa H 0.15 0.20 0.27 0.31 0.40 0.53 0.68 0.86
Noise dB(A) Static pressure of 12 Pa H 34.5 34.5 37.5 41.0 45.0 44.5 48.0 49.0
Static pressure of 30 Pa H 37.0 40.0 42.5 44.0 45.5 46.5 49.5 49.5
Noise dB(A) in sleep mode Static pressure of 12 Pa H 18.5 20.5 22.5 22.0 28.0 29.5 32.5 33.5
Static pressure of 30 Pa H 20.0 24.0 25.5 25.5 25.0 30.5 33.0 32.0
Water flow (m3/h) 0.32 0.51 0.67 0.80 0.88 1.31 1.47 1.81
Water resistance (cooling) (kPa) 5 14 26 36 18 40 28 40
Water resistance (heating) (kPa) 4 12 21 30 14 34 23 34
Coil Type Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners
Working pressure 1.6MPa
Test pressure Airtightness test under pressurized water: 3.3 MPa
Fan Type Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty. 1 2 2 2 2 3 4 4
Motor Type Ball-bearing brushless DC motor with a high precision and low noise
Qty. 1 1 1 1 1 2 2 2
Power supply 220V~/50Hz
Protection grade IP20
Insulation grade B
Inlet/outlet water pipe Pipe diameter Rc 3/4 taper pipe with internal threads
Condensate water pipe Pipe diameter R 3/4 Taper pipe with external threads
Net weight No return air plenum kg 10.4 12.3 14.6 15.4 16.2 24.4 27.1 29.4
With return air plenum kg 13.4 15.9 18.6 19.7 20.8 30.4 33.5 36.6

Notes:


■ Cooling capacity is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is
60°C, and the water flow is equal to that for cooling operation.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
■ The left/right orientation of connection pipes is exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor of 0.93 after exchange).

Specifications (two-pipe with 3 Rows of Coils)

Model
Performance
EKCW
200ACD
EKCW
300ACD
EKCW
400ACD
EKCW
500ACD
EKCW
600ACD
EKCW
800ACD
EKCW
1000ACD
EKCW
1200ACD
Rated air flow (m3/h; under static pressure of 12
Pa and 30 Pa)
H 340 510 680 850 1020 1360 1700 2040
M 279 418 558 697 836 1115 1394 1673
L 170 255 340 425 510 680 850 1020
Rated cooling capacity (W) Total heating/cooling capacity H 2260 3480 4490 5140 6450 8490 10030 11540
Sensible heating/cooling capacity H 1490 2170 2870 3600 4370 6080 7110 8500
Rated heating capacity (W) H 3610 5480 7050 7900 9770 13210 16230 18160
Rated input power (W) Static pressure of 12 Pa H 23 34 41 53 68 97 120 156
M 16 22 27 36 45 65 80 100
L 8 11 14 18 23 33 41 39
Static pressure of 30 Pa H 31 42 57 65 84 112 144 182
M 19 27 36 41 53 71 91 111
L 10 14 19 22 28 37 48 60
Working current (A) Static pressure of 12 Pa H 0.11 0.16 0.20 0.25 0.32 0.46 0.57 0.75
Static pressure of 30 Pa H 0.15 0.20 0.27 0.31 0.40 0.53 0.68 0.86
Noise dB(A) Static pressure of 12 Pa H 34.5 35.0 36.5 41.5 44.5 44.5 47.5 48.5
Static pressure of 30 Pa H 37.0 39.0 42.0 43.0 46.0 45.5 50.0 50.0
Noise dB(A) in sleep mode Static pressure of 12 Pa H 25.5 18.0 20.5 22.0 27.0 28.5 32.0 32.5
Static pressure of 30 Pa H 22.8 23.0 24.5 23.5 26.0 27.5 33.5 31.5
Water flow (m3/h) 0.44 0.61 0.74 0.96 1.10 1.54 1.75 2.10
Water resistance (cooling) (kPa) 13 30 17 24 36 36 29 40
Water resistance (heating) (kPa) 11 23 13 20 29 31 22 37
Coil Type Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners
Working pressure 1.6MPa
Test pressure Airtightness test under pressurized water: 3.3 MPa
Fan Type Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty. 1 2 2 2 2 3 4 4
Motor Type Ball-bearing brushless DC motor with a high precision and low noise
Qty. 1 1 1 1 1 2 2 2
Power supply 220V~/50Hz
Protection grade IP20
Insulation grade B
Inlet/outlet water pipe Pipe diameter Rc 3/4 taper pipe with internal threads
Condensate water pipe Pipe diameter R 3/4 Taper pipe with external threads
Net weight No return air plenum kg 11.1 13.3 15.7 16.6 17.6 26.4 29.2 31.8
With return air plenum kg 14.1 16.9 19.7 20.9 22.2 32.4 35.6 39.0

Notes:
■ Cooling capacity is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is
60°C, and the water flow is equal to that for cooling operation.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.
■ The left/right orientation of connection pipes is exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor of 0.93 after exchange).

Specifications (four-pipe with 2+1 Rows of Coils)

Model
Performance
EKCW
200AMD
EKCW
300AMD
EKCW
400AMD
EKCW
500AMD
EKCW
600AMD
EKCW
800AMD
EKCW
1000AMD
EKCW
1200AMD
Rated air flow (m3/h; under static pressure of 12
Pa and 30 Pa)
H 340 510 680 850 1020 1360 1700 2040
M 279 418 558 697 836 1115 1394 1673
L 170 255 340 425 510 680 850 1020
Rated cooling capacity (W) Total heating/cooling capacity H 1687 2642 3413 4105 4690 6620 7712 9350
Sensible heating/cooling capacity H 1112 1843 2496 3071 3676 5002 6162 7254
Rated cooling capacity (W) (chilled water coil) H 3081 4505 5889 7283 8590 11437 14186 16653
Rated heating capacity  (W) (hot water coil)   2360 3393 4397 5216 6182 7985 9672 11174
Rated heating capacity ‚ (W) (hot water coil)   3286 4856 6279 7391 8726 11242 13640 15834
Rated input power (W) Static pressure of 12 Pa H 23 34 41 53 68 97 120 156
M 16 22 27 36 45 65 80 100
L 8 11 14 18 23 33 41 39
Static pressure of 30 Pa H 31 42 57 65 84 112 144 182
M 19 27 36 41 53 71 91 111
L 10 14 19 22 28 37 48 60
Working current (A) Static pressure of 12 Pa H 0.11 0.16 0.20 0.25 0.32 0.46 0.57 0.75
Static pressure of 30 Pa H 0.15 0.20 0.27 0.31 0.40 0.53 0.68 0.86
Noise dB(A) Static pressure of 12 Pa H 34.5 35.0 36.5 41.5 44.5 44.5 47.5 48.5
Static pressure of 30 Pa H 37.0 39.0 42.0 43.0 46.0 45.5 50.0 50.0
Noise dB(A) in sleep mode Static pressure of 12 Pa H 25.5 18.0 20.5 22.0 27.0 28.5 32.0 32.5
Static pressure of 30 Pa H 22.8 23.0 24.5 23.5 26.0 27.5 33.5 31.5
Chilled water
coil
Water flow (m3/h) 1.33 1.50 1.63 1.75 1.85 2.18 2.36 2.67
Water resistance (cooling) (kPa) 5 12 19 29 14 31 22 36
Water resistance (heating) (kPa) 4 10 16 24 11 26 18 29
Hot water coil Water flow  (m3/h) 0.21 0.30 0.39 0.46 0.55 0.71 0.85 0.98
Water resistance (heating)  (kPa) 7 14 25 35 52 17 26 37
Water flow ‚ (m3/h) 0.13 0.20 0.25 0.30 0.36 0.46 0.55 0.64
Water resistance (heating) ‚ (kPa) 3 7 11 16 23 8 11 17
Coil Type Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners
Working pressure 1.6MPa
Test pressure Airtightness test under pressurized water: 3.3 MPa
Fan Type Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty. 1 2 2 2 2 3 4 4
Motor Type Ball-bearing brushless DC motor with a high precision and low noise
Qty. 1 1 1 1 1 2 2 2
Power supply 220V~/50Hz
Protection grade IP20
Insulation grade B
Inlet/outlet water pipe Pipe diameter Rc 3/4 taper pipe with internal threads
Condensate water pipe Pipe diameter R 3/4 Taper pipe with external threads
Net weight No return air plenum kg 11.1 13.3 15.7 16.6 17.6 26.4 29.2 31.8
With return air plenum kg 14.1 16.9 19.7 20.9 22.2 32.4 35.6 39.0

Notes:
■ Cooling capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the water flow is equal to that for cooling operation.
■ Heating capacity  (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the temperature of outlet water is 50°C.
■ Heating capacity  (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 82.2°C, and the temperature of outlet water is 60°C.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.

Specifications (four-pipe with 3+1 Rows of Coils)

Model
Performance
EKCW
200AHD
EKCW
300AHD
EKCW
400AHD
EKCW
500AHD
EKCW
600AHD
EKCW
800AHD
EKCW
1000AHD
EKCW
1200AHD
Rated air flow (m3/h; under static pressure of 12
Pa and 30 Pa)
H 340 510 680 850 1020 1360 1700 2040
M 279 418 558 697 836 1115 1394 1673
L 170 255 340 425 510 680 850 1020
Rated cooling capacity (W) Total heating/cooling capacity H 2530 3310 4240 5000 5890 8040 9290 11820
Sensible heating/cooling capacity H 1490 2100 2850 3350 4040 5520 6730 8300
Rated cooling capacity (W) (chilled water coil) H 4180 5300 7030 7920 9890 13120 16120 20150
Rated heating capacity  (W) (hot water coil)   2450 3170 4090 4470 5690 7290 8790 11610
Rated heating capacity ‚ (W) (hot water coil)   3330 4240 5800 6670 7970 10200 12270 16420
Rated input power (W) Static pressure of 12 Pa H 23 34 41 53 68 97 120 156
M 16 22 27 36 45 65 80 100
L 8 11 14 18 23 33 41 39
Static pressure of 30 Pa H 31 42 57 65 84 112 144 182
M 19 27 36 41 53 71 91 111
L 10 14 19 22 28 37 48 60
Working current (A) Static pressure of 12 Pa H 0.11 0.16 0.20 0.25 0.32 0.46 0.57 0.75
Static pressure of 30 Pa H 0.15 0.20 0.27 0.31 0.40 0.53 0.68 0.86
Noise dB(A) Static pressure of 12 Pa H 33.5 32.5 38.5 41.5 44.5 45.0 48.0 49.0
Static pressure of 30 Pa H 39.5 40.0 43.0 44.0 46.0 46.0 50.5 50.5
Noise dB(A) in sleep mode Static pressure of 12 Pa H 18.9 19.0 23.1 21.5 29.1 30.7 32.0 32.8
Static pressure of 30 Pa H 20.9 23.3 26.8 25.0 28.3 30.4 35.9 33.8
Chilled water
coil
Water flow (m3/h) 0.44 0.57 0.73 0.88 1.03 1.41 1.62 2.04
Water resistance (cooling) (kPa) 14 29 17 24 33 34 26 44
Water resistance (heating) (kPa) 11 21 13 21 26 27 21 36
Hot water coil Water flow  (m3/h) 0.21 0.27 0.35 0.38 0.49 0.63 0.75 0.97
Water resistance (heating)  (kPa) 7 14 22 28 54 15 21 40
Water flow ‚ (m3/h) 0.13 0.17 0.23 0.26 0.31 0.40 0.48 0.63
Water resistance (heating) ‚ (kPa) 3 6 10 14 20 7 10 18
Coil Type Shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners
Working pressure 1.6MPa
Test pressure Airtightness test under pressurized water: 3.3 MPa
Fan Type Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty. 1 2 2 2 2 3 4 4
Motor Type Ball-bearing brushless DC motor with a high precision and low noise
Qty. 1 1 1 1 1 2 2 2
Power supply 220V~/50Hz
Protection grade IP20
Insulation grade B
Inlet/outlet water pipe Pipe diameter Rc 3/4 taper pipe with internal threads
Condensate water pipe Pipe diameter R 3/4 Taper pipe with external threads
Net weight No return air plenum kg 11.8 14.3 16.8 17.9 19.1 28.4 31.4 34.3
With return air plenum kg 14.8 17.9 20.8 22.2 23.7 34.4 37.8 41.5

Notes:
■ Cooling capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry/wet bulb is 27°C/19.5°C and the temperature of inlet/outlet water is 7°C/12°C.
■ Heating capacity (chilled water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the water flow is equal to that for cooling operation.
■ Heating capacity  (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 60°C, and the temperature of outlet water is 50°C.
■ Heating capacity  (hot water coil) is measured under working conditions where the temperature of inlet air dry bulb is 21°C, the temperature of inlet water is 82.2°C, and the temperature of outlet water is 60°C.
■ Rated air flow is measured under standard atmosphere using dry coils (the temperature of dry bulb is 20°C).
■ Sound pressure grade and noise level are measured in a semi-silent room as per GB/T 19232-2003.
■ Sleep mode: In auto control mode, the unit can use the control logic to determine whether to enter the sleep mode based on the real-time load of the room.
■ H, M, and L indicate high, medium, and low fan speed respectively.
■ Static pressure refers to the outlet static pressure of the unit.
■ All performance parameters in the preceding table are measured with a power supply of 220V~/50Hz.

Description:

EKCW Series Brushless DC Fan Coils

EKCW series brushless DC fan coils use the latest patented brushless DC technologies developed jointly by EUROKLIMAT (EK) and China Aerospace Science & Industry Corp (CASIC) and the leading-edge air processing technologies to implement stepless speed regulation. These fan coils can automatically regulate the rotation speed of motors based on the indoor load variation to maximize energy saving (saving energy by more than 65% compared with common fan coil systems). More than 300 models in the full series of units are available for customers.

Features

Efficient and Energy Saving

The unit is designed and manufactured to work withEK's efficient heat exchangers. Compared with the fan coil of a traditional AC motor, the unit saves energy by more than 65% as a whole, reducing the energy consumption for the entire HVAC system by 14%–18%.

Taking EKCW400AC1 as an example:

High Efficiency DC Brushless Horizontal Concealed Fan Coil UnitHigh speed:

Traditional fan coil - 64.0 W

Brushless DC fan coil - 46.2 W

High Efficiency DC Brushless Horizontal Concealed Fan Coil UnitMedium speed:

Traditional fan coil - 56.9W

Brushless DC fan coil - 20.9W

High Efficiency DC Brushless Horizontal Concealed Fan Coil UnitLow speed:

Traditional fan coil - 46.1W

Brushless DC fan coil - 8.4W

Item

High speed

Medium speed

Low speed

Traditional fan coil

64.0W

56.9W

46.1W

EK's brushless DC fan coil

46.2 W

20.9 W

8.4 W

Energy Saving

27.8%

63.3%

81.8%

Test Results

The unit saves energy by 20%–35% at the nominal high speed, by 45%–65% at the nominal medium speed, and by 65%–85% at the nominal low speed.

Generally, a fan coil reaches the set temperature within one hour after power-on, and then runs at a low or medium speed.

Objective calculation shows that EKCW series brushless DC fan coils save energy by 65% compared with traditional fan coils.

Fast Cooling/Heating

Due to a major difference between the indoor temperature and the set temperature in the initial phase of power-on, the powerful cooling/heating function of the unit can regulate the indoor temperature to the set one within a short period and control the air flow based on the actual load of the room, saving energy and generating less noise.

Due to a low temperature control precision (±2°C), traditional fan coils usually require a set temperature of 20°C–22°C to prevent unpredictable temperature changes in hot summer. Due to a high temperature control precision ((±0.5°C), EKCW brushless DC fan coils allow a set temperature of 26°C (comfortable temperature).

Constant Temperature and Comfort

EKCW brushless DC fan coils can perform proportion integration (PI) calculation based on the variation between the indoor temperature and the set temperature. These fan coils can intelligently adjust the rotation speed and air supply volume of motors within a wide range, and provide a temperature control precision of ±0.5°C, creating real and comfortable indoor environment with constant temperature.

EKCW brushless DC fan coils feature the unique sleep mode, in which the lowest noise level is only 18 dB(A), creating comfortable indoor environment with constant temperature for customers and providing a fresh and comfortable 3-D sleep space.

Strong Dehumidification

Traditional fan coils support the following operation modes: cooling, heating,and air supply (high/medium/low). EKCW series brushless DC fan coils support the following operation modes: cooling, heating, dehumidification, air supply, auto control, sleep, strong

cooling, strong heating, strong dehumidification, timing setting, fire alarm, automatic temperature control in standby mode, 2-way/3-way valve protection, and network-based control (RS485).

Optional accessories: PTC electric heater, UV+photocatalyst for sterilization, condensate water lifting pump, and anti-blocking float switch.

Adjustable Static Pressure

Traditional fan coils adapt to only one outlet static pressure. If the on-site static pressure is improper, the motor must be replaced. EKCW series brushless DC fan coils can adapt to the outlet static pressure of 0–50 Pa. The outlet static pressure can be directly adjusted on site based on temperature controller settings without replacing the motor.

Smooth Operation and Low Noise

The unit uses a forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates, featuring low noise, high wind speed, and smooth operation, and achieving the best result of air supply.

High Quality and Reliability

All coils use shutter-type hyperbolic and hydrophilic fins made from mechanically expanded quality copper tubes specially designed for air conditioners. All coils are subject to leakage-free test under a pressure of 3.3 MPa, and are strictly inspected before they leave the factory, ensuring high performance and reliability.

No Condensation

The unit uses a condensate water collector that is molded as a whole, and features enhanced heat preservationfor the water collector and innovative batter drainage structure, effectively eliminating generation and dripping of condensation.

Even Air Supply

The unit features a rational air flow design for air supply and return so that air is evenly supplied to all corners of the room, making the room feel comfortable.

Efficient Sterilization

The unit uses sterilization technologies of nano-TiO2 photocatalyst to achieve a sterilization rate of 95%, considerably improving the air quality for work and life.

Flexible Application

The unit features the single-area controlled design, and therefore can match the master unit of any central air conditioning systems with centralized cooling/heating.

Easy Installation

With a compact, graceful, and robust design, the super-thin (only 230 mm thick) unit can be easily installed.

Leading-edge Control Technologies

The unit uses industry-leading water system control technologies and temperature control technologies to save energy during system operation.

No Electromagnetic Interference

The unit does not generate high-frequency harmonic and electromagnetic interference during stepless regulation.Therefore, the unit can be widely used in places with strict anti-interference requirements for power supply, including computer rooms, telecom base stations, TV and broadcast receiving stations, and communication equipment rooms.

Applications:

Office, Hotel , Hospital ,Supermarket ,Airport , Factory ,Villa .

Competitive Advantage:

Super Energy Saving Saves energy by more than 65%

Constant Temperature and Comfort The precision of silent temperature control reaches ±0.5°C.

Fast Cooling/Heating The speed increases by 30%.

EK Patents CASIC and EK's patents

Strong Dehumidification Outstanding dehumidifying results

Adjustable Static Pressure Adjustable static pressure of 0–50 Pa


Product Tags:

chilled water fan coil unit

      

air conditioning Fan Coil Unit

      
Quality High Efficiency DC Brushless Horizontal Concealed Fan Coil Unit for sale

High Efficiency DC Brushless Horizontal Concealed Fan Coil Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0